High insertion torque linked to poorer long-term dental implant outcomes :- Medznat
EN | RU
EN | RU

Help Support

By clicking the "Submit" button, you accept the terms of the User Agreement, including those related to the processing of your personal data. More about data processing in the Policy.
Back

Greater bone loss and pain reported with very high dental implant torque

Dental pain, Dental implants Dental pain, Dental implants
Dental pain, Dental implants Dental pain, Dental implants

What's new?

Dental implants placed with insertion torque exceeding 100 Ncm show higher postoperative pain, greater marginal bone loss, and lower 3-year survival rates than implants placed with moderate torque levels.

A prospective study published in "Quintessence International" by Ahmed M Aziz et al. evaluated short- and long-term clinical outcomes of dental implants placed with different insertion torque (IT) levels over a 36-month follow-up period. Researchers enrolled patients requiring single-tooth dental implants and categorized them according to IT values into:

  • Low IT: 10–29 Ncm
  • Regular IT: 30–50 Ncm
  • High IT: 51–100 Ncm
  • Very high IT: >100 Ncm

Clinical outcomes assessed during the 3-year follow-up included implant survival, implant success, marginal bone loss, and postoperative pain. The degree of pain was checked via a 10-cm visual analog scale (VAS) at distinct postoperative time points ranging from immediately after surgery to week 3. Survival analyses were performed using Kaplan-Meier and Cox regression models, while multivariate analyses identified predictors associated with marginal bone loss and postoperative pain.

The results showed that 230 patients underwent dental implant placement. Patients in the very high IT group reported markedly greater postoperative pain at week 3 compared with other groups (Table 1).

The study concluded that excessively high IT negatively affected long-term implant performance by increasing postoperative pain, marginal bone loss, and implant failure risk. The combined influence of dense bone conditions, smoking-related impaired healing, and anatomically vulnerable maxillary regions further contributed to unfavorable outcomes. These results emphasized the importance of maintaining optimal IT levels to improve implant longevity and peri-implant bone stability.

Source:

Quintessence International

Article:

Clinical outcomes of dental implants placed with varying insertion torques: a 3-year prospective analysis

Authors:

Ahmed M Aziz et al.

Comments (0)

You want to delete this comment? Please mention comment Invalid Text Content Text Content cannot me more than 1000 Something Went Wrong Cancel Confirm Confirm Delete Hide Replies View Replies View Replies en ru
Try: